AVENTICS AES Series Bus Coupler,DeviceNet, 24 VDC, Short Circuit, Undervoltage
Manufacturer: Asco LP
Mfg Product Code: R412018221
Weight: 2.0 lb(s)
Bus Coupler,DeviceNet, 24 VDC, Short Circuit, Undervoltage
The AVENTICS Series AES fieldbus connection can be integrated into all AVENTICS fieldbus-compatible valve systems or can also be configured as a stand-alone solution. AES connects your AVENTICS valve system to all relevant fieldbus protocols and offers the integration of I/O-modules and enables optimized decentralized wiring of sensors. The integration of the Digital Twin enables users to be IIoT ready and use the AES to solve their interoperability challenges.
Features
- Version: Bus coupler
- Fieldbus protocol:DeviceNet
- E/A capable: connection with I/O
- Number of I/O connections: 512 inputs / 512 outputs
- Power plug IN type: Plug
- Power plug IN size: M12x1
- Power plug IN number of pole: 4-pin
- Power plug IN coding: A-coded
- Fieldbus design: D-design
- Min. ambient temperature: -10 °C
- Max. ambient temperature: 60 °C
- Number of solenoid coils max.: 128
- Max. number of valve positions: 64
- Operational voltage electronics: 24 V DC
- Electronics voltage tolerance: -25% / +25%
- Power consumption electronics: 0.1 A
- Operating voltage, actuators: 24 V DC
- Total current for actuators: 4 A
- Protection class: IP65
- Cycle time at 256 bits: < 1 ms
- Logic/actuator voltage: Galvanically isolated
- Diagnosis: Short circuit, Undervoltage
- I/O module extension max.: 10
- Generic emission standard in accordance with norm: EN 61000-6-4
- Generic immunity standard in accordance with norm: EN 61000-6-2:
AVENTICS AES Series Bus Coupler,DeviceNet, 24 VDC, Short Circuit, Undervoltage
Bus Coupler,DeviceNet, 24 VDC, Short Circuit, Undervoltage
Current:≤4 A
Power Consumption:0.1 A
Input Voltage:24 VDC
Ingress Protection:IP65
Electrical Connector Type:A-Coded 4-Pin M12X1 Plug
No. I/O Connections:512/512
Cycle Time:<1 ms @ 256 bits
Logic/Actuator Voltage:Galvanically Isolated
Diagnosis:Short Circuit, Undervoltage
Fieldbus Protocol:DeviceNet
No. Max I/O Module Ext:10
No. Max Valve Positions:64
No. Max Solenoid Coils:128
Voltage Tolerance: -25% / +25%
Specifications
Current | ≤4 A |
Power Consumption | 0.1 A |
Input Voltage | 24 VDC |
Ingress Protection | IP65 |
Electrical Connector Type | A-Coded 4-Pin M12X1 Plug |
No. I/O Connections | 512/512 |
Cycle Time | <1 ms @ 256 bits |
Logic/Actuator Voltage | Galvanically Isolated |
Diagnosis | Short Circuit, Undervoltage |
Fieldbus Protocol | DeviceNet |
No. Max I/O Module Ext | 10 |
No. Max Valve Positions | 64 |
No. Max Solenoid Coils | 128 |
Voltage Tolerance | -25% / +25% |