Representative photo. Please check item description for details.
Krohne Optiwave 3500 Radar Level Transmitter
Manufacturer: Krohne Inc
Mfg Product Code:
On Hand: 0
80 GHz Radar (FMCW) Level Transmitter for liquids with hygienic requirements
Highlights
- KROHNE is the pioneer of FMCW radar level measurement and has more than 30 years of experience with this technology
- 2-wire loop-powered 80 GHz transmitter – HART® 7
- Accuracy: ±2 mm / ±0.08¨
- PEEK Lens antenna measures distances up to 50 m / 164 ft at +150°C / +302°F and 25 barg / 362 psig
- Extensive choice of hygienic process connections: Tri-Clamp, Tuchenhagen VARIVENT®, SMS, DIN 11851, DIN 11864, NEUMO BioControl®
- Small dead zone and beam angle (8° with DN40 / 1½¨ Lens antenna, 10° with DN25 / 1¨)
- Extensive choice of hygienic process connections (ideal for cleaning-in-place / sterilizationin-place (CIP-SIP) processes)
- One user interface for all applications
- Empty tank spectrum function eliminates false reflections caused by tank internals
- Diagnosis functions according to NAMUR NE 107
- Conforms to NAMUR Recommendations NE 21, NE 43 and NE 53
- Can measure in fast moving processes (≤60 m/min / 196.85 ft/min)
Krohne Optiwave 3500 Radar Level Transmitter
Outputs:[1] 2-wire / 4...20mA passive HART
Process Seal / Temperature Range:[02] PEEK / (-14.5... +362 psig) / (-40°F...+302°F)
Specifications
Regional Directives | [3] USA or [4] Canada |
Hazardous Area Approvals | [0] General Purpose (Non-Hazardous Area) or [B] cQPSus Class I Div 1 Explosion Proof or [A] cQPSus Class I Div 1 Intrinsically Safe or [C] cQPSus Class I Div 2 Non-Incendive |
Construction Approval | [B0] Without or [B2] CRN / ASME B31.3 |
Housing Material | [2] Aluminum Housing or [3] Stainless Steel |
Cable Entry / Gland | [C] (2) 1/2" NPT nickel-plated brass adaptor / without or [D] (2) 1/2" NPT nickel-plated brass adaptor / (1) Gland (1) Plug or [E] (2) 1/2" NPT stainless steel adaptor / (1) Gland (1) Plug or [F] (2) 1/2" NPT nickel-plated brass adaptor / (2) Gland or [G] (2) 1/2" NPT stainless steel adaptor / (2) Gland |
Display | [41] Plug-in display (cover with window) or [01] Without (cover with window) |
Antenna | [2] 1" PEEK Lens * Closed Tank Only or [3] 1.5" PEEK Lens |
Process Connection | [0GFS] 1.5" Tri-Clamp or [0HFS] 2" Tri-Clamp |
Optional Electropolished Parts | [0] Without or [2] Electropolished Metallic Wetted Parts |
Accessories / Tag Plate | [0] Without or [1] Stainless Steel Weather Protection or [3] Stainless Steel Tag Plate, Add Tag # (18 char max) or [6] Stainless Steel Weather Protection and Tag Plate, Add Tag # (18 char max) |
Calibration Certificate | [0] Without: Accuracy ±0.08" or [1] ±0.08" Accuracy up to 32.81 ft 2 points or [2] ±0.08" Accuracy up to 32.81 ft 5 points or [3] ±0.08" Accuracy up to 32.81 ft 5 points specified by the customer min. ≥ 39.4" |
Outputs | [1] 2-wire / 4...20mA passive HART |
Process Seal / Temperature Range | [02] PEEK / (-14.5... +362 psig) / (-40°F...+302°F) |