Krohne MFC 400 Flow Converter
Manufacturer: Krohne Inc
Mfg Product Code:
On Hand: 0
Signal converter for mass flowmeters
- High performance signal converter for all applications, developed according to IEC 61508, SIL 2/3
- Stable in multi-phase applications due to Entrained Gas Management (EGM™)
- Smart diagnostics according to NAMUR NE 107
Highlights
- High performance signal converter with multiple output options
- Developed according to IEC 61508
- Safe configuration via local display or HART®
- Partial proof test capable
- Smart diagnostics, covering entire devices in less than a minute
- NE 107 status indicated by display background light
- Entrained Gas Management (EGMTM): meter maintains operation over a wide range of gas fractions and complex flow conditions
- Excellent long-term stability
- Optical and mechanical keys for ease of use
- Redundant data storage in signal converter housing
- Real time clock for logging events
- Overall, flexible lock concept
- HART® 7
- Communication interfaces for integration into third party systems via HART® (as standard), Modbus, FOUNDATION™ Fieldbus, PROFIBUS®, PROFINET IO and EtherNet/IP®
- Device commissioning, verification, diagnostics and monitoring can be transmitted via secure wireless Bluetooth® connection (<20 m / 65.6 ft)
Krohne MFC 400 Flow Converter
Specifications
Housing Type | [4] C-Compact or [H] F-Field Mounted |
Power Supply | [1] 12-24 V DC or [4] 24 V DC / AC or [A] 100-230 V AC |
Hazardous Area Approvals | [0] General Purpose (Non-Hazardous Area) or [7] cFMus Class I DIV 1 or [A] Non Ex (US) or [B] Non Ex (Canada) |
Cable Connection | [42] 1/2" NPT or [R2] 1/2" NPT Stainless Steel |
Custody Transfer | [00] Without or [A0] With CT Lock Facility or With CT Lock Facility for NTEP |
Converter Housing | [10] Die-Cast Aluminum (Polyurethane Coated) or [20] 316 Stainless Steel - C or [30] 316 Stainless Steel - F |
Outputs/Communication | [1] 4-20 mA / HART + Pulse / Frequency + Status + Control or [4] Current Active + Pulse Active/high current or [6] Current Active + Pulse Passive/high current or [7] Current Active + Pulse Passive/Namur or [8] Current Passive + Pulse Active/high current or [B] Current Passive + Pulse Passive/high current or [C] Current Passive + Pulse Passive/Namur or [D] Profibus PA or [E] Foundation Fieldbus or [F] Profibus DP or [G] RS 485 Modbus or [H] RS 485 Modbus w/ termination resistor |
1st IO Module | [0] No Module Possible or [8] Without Module or [A] Current Active or [B] Current Passive or [C] Pulse Active/high current or [E] Pulse Passive/high current or [F] Pulse Passive/Namur or [G] Control Input Active/high current or [H] Control Input Active/Namur or [K] Control Input Passive/high current |
2nd IO Module | [0] No Module Possible or [8] Without Module or [A] Current Active or [B] Current Passive or [C] Pulse Active/high current or [E] Pulse Passive/high current or [F] Pulse Passive/Namur or [G] Control Input Active/high current or [H] Control Input Active/Namur or [K] Control Input Passive/high current |
Measuring Functions | [00] Standard (mass, density, temp, vol.) or [10] Standard + Brix or [20] Standard + General Concentration or [30] Standard + Baume 144.3 or [40] Standard + Baume 145 or [50] Standard + NaOH or [60] Standard + Plato or [A0] Standard + API oil standard or [B0] Standard + Alcohol |
Signal Cable Length | [OU] No Cable Required or [4U] 15ft or [1U] 30ft or [6U] 45ft or [5U] 60ft |
Paired Sensor | [1] Optimass 1000 or [2] Optimass 2000 or [3] Optimass 3000 or [6] Optimass 6000 - 08-100 Size or [A] Optimass 6000 08-100 Short Stem or [B] Optimass 6000 150-250 (not SIL Compliant) or [C] Optimass 6000 150-250 Short Stem (not SIL Compliant) or [7] Optimass 7000 or [0] Without (spare electronics) |