EPI - 8800 Series Flowmeter, Hazardous Area Insertion, 1/2" ProbeLocation
Manufacturer: Eldridge Products - EPI
Mfg Product Code: 8840MP-INT -SSS-133- DC24-MW050-4012NA-1RC-AIR-CT2-MB
Weight: 5.0 lb(s)
8840MP - Hazardous Area Insertion Style Flow Meter - 1/2" OD Probe
INT - Integral Electronics - Standard two analog signal (4-20mA and 0-5VDC flow & temperature) and one digital output
(RS485 Modbus RTU). OPTIONAL DIGITAL OUTPUTS: HART, BACnet, or Profibus.
SSS - 316L stainless steel thermal wells - 50Ω reference grade platinum winding on ceramic rod with dielectric glass coating bonded
by epoxy buffer.
133 - 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button programmable keypad;
OUTPUT: Flow, Total Flow, % of Full Scale, Temperature, Raw mW Cooling
DC24 - 24 VDC
MW050- Gas Temperature Range: Ambient to 50°C/122°F
4012NA- 1/2" OD x 12" Probe
1RC - 1 Gas Range
AIR - AIR calibration against our certified 0.05% accurate Primary Standard that is directly traceable to NIST. Enhanced accuracy
calibration is always optional.
CT2 - CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with display); Approved
for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in hazardous area locations; Class I
Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d
IIB+H2 IP66; T2; Ta = 0°C to 50°C
MB - RS485 Modbus RTU - Read & Write
TPM0808T -1/2" tube x 1/2" male pipe thread, bored thru fitting with Teflon ferrule
EPI - 8800 Series Flowmeter, Hazardous Area Insertion, 1/2" ProbeLocation
8840MP - Hazardous Area Insertion Style Flow Meter - 1/2" OD Probe
INT - Integral Electronics - Standard two analog signal (4-20mA and 0-5VDC flow & temperature) and one digital output
(RS485 Modbus RTU). OPTIONAL DIGITAL OUTPUTS: HART, BACnet, or Profibus.
SSS - 316L stainless steel thermal wells - 50Ω reference grade platinum winding on ceramic rod with dielectric glass coating bonded
by epoxy buffer.
133 - 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button programmable keypad;
OUTPUT: Flow, Total Flow, % of Full Scale, Temperature, Raw mW Cooling
DC24 - 24 VDC
MW050- Gas Temperature Range: Ambient to 50°C/122°F
4012NA- 1/2" OD x 12" Probe
1RC - 1 Gas Range
AIR - AIR calibration against our certified 0.05% accurate Primary Standard that is directly traceable to NIST. Enhanced accuracy
calibration is always optional.
CT2 - CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with display); Approved
for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in hazardous area locations; Class I
Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d
IIB+H2 IP66; T2; Ta = 0°C to 50°C
MB - RS485 Modbus RTU - Read & Write
TPM0808T -1/2" tube x 1/2" male pipe thread, bored thru fitting with Teflon ferrule
Brand_Name:Eldridge
Measurement Minimum:0
Specifications
Brand_Name | Eldridge |
Measurement Minimum | 0 |