Representative photo. Please check item description for details.

Series 8600-8700MP Inline Thermal Mass Flow Meter, Modbus Output, 24VDC Power, 1 1/2"NPT Pipe

https://www.branom.com/web/image/product.template/505124/image_1920?unique=9118285
(0 review)

Manufacturer: Eldridge Products - EPI

Mfg Product Code: 8712MP-INT -SSS-133- DC24-MW050-S4012MTP2-1RC-NG-CT2-MB

Weight: 20.0 lb(s)

Usually Ships Within 1 - 2 Weeks

8712MP‐ Hazardous Area In-line Style Flow Meter - 1 1/2" x 14"

INT‐ Integral Electronics - standard outputs: 0-5VDC & 4-20mA (flow with optional temperature), RS485
Modbus RTU. 4-20mA Modbus is enabled.

SSS‐ 316L stainless steel sensor. OPTIONAL - sensor with attenuating rod, sensor with particle sensor shield,
or Hastelloy® C-276 sensor

133‐ 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button
programmable key-pad; OUTPUT: Flow, Total Flow, % of Full Scale, Temperature, Raw mW Cooling

DC24‐ 24 VDC

MW050‐ Gas Temperature Range: Ambient to 50°C/122°F

S4012MTP2‐ 1 1/2" Sch 40 Stainless Steel 316L x 14" Section - MNPT ends - flow screens

1RC‐ 1 Gas Range

NG‐ NATURAL GAS calibration against our certified 0.05% accurate Primary Standard that is directly
traceable to NIST. Enhanced accuracy calibration is always optional.

CT2‐ T2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with
display); Approved for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in
hazardous area locations; Class I Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type
4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d IIB+H2 IP66; T2; Ta = 0°C to 50°C

MB‐ RS485 Modbus RTU - Read & Write


4,450.00 4450.0 USD 4,450.00

4,450.00

Not Available For Sale

  • Brand_Name
  • Measurement Maximum
  • Process Connection Type
  • Process Connection Size
  • Measurement Minimum
  • Output Communication Protocol
  • Input Voltage

This combination does not exist.

Series 8600-8700MP Inline Thermal Mass Flow Meter, Modbus Output, 24VDC Power, 1 1/2"NPT Pipe

  • Brand_Name
  • Measurement Maximum
  • Process Connection Type
  • Process Connection Size
  • Measurement Minimum
  • Output Communication Protocol
  • Input Voltage

4,450.00 4450.0 USD 4,450.00

4,450.00

Not Available For Sale

This combination does not exist.


8712MP‐ Hazardous Area In-line Style Flow Meter - 1 1/2" x 14"

INT‐ Integral Electronics - standard outputs: 0-5VDC & 4-20mA (flow with optional temperature), RS485
Modbus RTU. 4-20mA Modbus is enabled.

SSS‐ 316L stainless steel sensor. OPTIONAL - sensor with attenuating rod, sensor with particle sensor shield,
or Hastelloy® C-276 sensor

133‐ 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button
programmable key-pad; OUTPUT: Flow, Total Flow, % of Full Scale, Temperature, Raw mW Cooling

DC24‐ 24 VDC

MW050‐ Gas Temperature Range: Ambient to 50°C/122°F

S4012MTP2‐ 1 1/2" Sch 40 Stainless Steel 316L x 14" Section - MNPT ends - flow screens

1RC‐ 1 Gas Range

NG‐ NATURAL GAS calibration against our certified 0.05% accurate Primary Standard that is directly
traceable to NIST. Enhanced accuracy calibration is always optional.

CT2‐ T2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with
display); Approved for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in
hazardous area locations; Class I Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type
4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d IIB+H2 IP66; T2; Ta = 0°C to 50°C

MB‐ RS485 Modbus RTU - Read & Write


Brand_Name:Eldridge
Measurement Maximum:0
Process Connection Type:NPT
Process Connection Size:1-1/2"
Measurement Minimum:0
Output Communication Protocol:Modbus
Input Voltage:12 VDC


Specifications

Brand_Name Eldridge
Measurement Maximum 0
Process Connection Type NPT
Process Connection Size 1-1/2"
Measurement Minimum 0
Output Communication Protocol Modbus
Input Voltage 12 VDC