EPI, 8100MP Series, 2inch Sch. 40 Stainless Steel

https://www.branom.com/web/image/product.template/513564/image_1920?unique=9118285
(0 review)

Manufacturer: Eldridge Products - EPI

Mfg Product Code: 8116MP-REM-SSS-133- DC24-MW050-S4016FL1516P2-1RC-C3H8-CT2-MB

Weight: 20.0 lb(s)

On Hand: 0

8116MP- Hazardous Area In-line Style Flow Meter- 2" x 18" (Custom Flow Section)

REM- Remote Electronics for use in Ordinary Locations ONLY - Class 2252-03 & 2252-83 for Process Control Equipment: Standard two analog
signal(20mA and 0-5VDC flow & temperature) and one digital output (RS485 Modbus RTU). OPTIONAL DIGITAL OUTPUTS: HART, BACnet, or
Profibus.

SSS- 316L stainless steel thermal wells - 50Ω reference grade platinum winding on ceramic rod with dielectric glass coating bonded by epoxy buffer.

133- 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button programmable keypad; OUTPUT: Flow,
Total Flow, Full Scale, Temperature, Raw mW Cooling

DC24- 24 VDC

MW050- Gas Temperature Range: Ambient to 50°C/122°F

S4016FL1516P2- 2" SCH 40 Stainless Steel 316L x 18" (Custom Length) Section - 2" 150# RF flange ends - flow screens

1RC- 1 Gas Range

C3H8- PROPANE calibration against our certified 0.05% accurate Primary Standard that is directly traceable to NIST.accuracy calibration is always optional.


CT2- CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with display); Approved
for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in hazardous area locations; Class I
Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d
IIB+H2 IP66; T2; Ta = 0°C to 50°C

MB- RS485 Modbus RTU - Read & Write

8116MP- Hazardous Area In-line Style Flow Meter- 2" x 18" (Custom Flow Section) REM- Remote Electronics for use in Ordinary Locations ONLY - Class 2252-03 & 2252-83 for Process Control Equipment: Standard two analog signal(20mA and 0-5VDC flow & temperature) and one digital output (RS485 Modbus RTU). OPTIONAL DIGITAL OUTPUTS: HART, BACnet, or Profibus. SSS- 316L stainless steel thermal wells - 50Ω reference grade platinum winding on ceramic rod with dielectric glass coating bonded by epoxy buffer. 133- 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button programmable keypad; OUTPUT: Flow, Total Flow, Full Scale, Temperature, Raw mW Cooling DC24- 24 VDC MW050- Gas Temperature Range: Ambient to 50°C/122°F S4016FL1516P2- 2" SCH 40 Stainless Steel 316L x 18" (Custom Length) Section - 2" 150# RF flange ends - flow screens 1RC- 1 Gas Range C3H8- PROPANE calibration against our certified 0.05% accurate Primary Standard that is directly traceable to NIST.accuracy calibration is always optional. CT2- CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with display); Approved for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in hazardous area locations; Class I Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d IIB+H2 IP66; T2; Ta = 0°C to 50°C MB- RS485 Modbus RTU - Read & Write


  • Brand
  • Measurement Minimum

This combination does not exist.

EPI, 8100MP Series, 2inch Sch. 40 Stainless Steel

  • Brand
  • Measurement Minimum

0.00 0.0 USD 0.00

0.00

Not Available For Sale

This combination does not exist.


8116MP- Hazardous Area In-line Style Flow Meter- 2" x 18" (Custom Flow Section)

REM- Remote Electronics for use in Ordinary Locations ONLY - Class 2252-03 & 2252-83 for Process Control Equipment: Standard two analog
signal(20mA and 0-5VDC flow & temperature) and one digital output (RS485 Modbus RTU). OPTIONAL DIGITAL OUTPUTS: HART, BACnet, or
Profibus.

SSS- 316L stainless steel thermal wells - 50Ω reference grade platinum winding on ceramic rod with dielectric glass coating bonded by epoxy buffer.

133- 2-line backlit Liquid Crystal Transflective Display - excellent low light and high light readability; 4-button programmable keypad; OUTPUT: Flow,
Total Flow, Full Scale, Temperature, Raw mW Cooling

DC24- 24 VDC

MW050- Gas Temperature Range: Ambient to 50°C/122°F

S4016FL1516P2- 2" SCH 40 Stainless Steel 316L x 18" (Custom Length) Section - 2" 150# RF flange ends - flow screens

1RC- 1 Gas Range

C3H8- PROPANE calibration against our certified 0.05% accurate Primary Standard that is directly traceable to NIST.accuracy calibration is always optional.


CT2- CT2: CSA/CUS T2 (300°C) Approved Instrument for Flow Element/Flow Transmitter (FE/FT or FIT with display); Approved
for remote electronics (FIT or FT) only with remote ACEX or DCEX feature; For use in hazardous area locations; Class I
Division 1, Group B, C, D; Class II Group E, F, G; Class III; Enclosure Type 4X; Class I Zone I; AEx d IIB+H2 IP66; Ex d
IIB+H2 IP66; T2; Ta = 0°C to 50°C

MB- RS485 Modbus RTU - Read & Write


Brand:Eldridge
Measurement Minimum:0


Specifications

Brand Eldridge
Measurement Minimum 0