Features:

    Laser Displacement Sensor; Range: 100-1000 mm; Input:12-30 V dc; Output: Analog: 4-20 mA; Discrete: NPN/PNP configurable; Integral Quick-Disconnect; w/o Banner from startup

1,138.00 1138.0 USD 1,138.00

1,138.00

Not Available For Sale

  • Brand
  • Max Off-State Leakage Current (µA)
  • Analog Current Output Rating
  • Min Operating Temperature
  • Max Operating Temperature
  • Power/Current Consumption (exclusive of load)
  • Power Supply
  • Temperature Effect (mm/°C)
  • Delay at Power-Up
  • Ingress Protection
  • Sensing Beam
  • Sensing Beam Wavelength
  • Housing Style
  • Max Sensing Distance
  • Sensing Mode (Detailed)
  • Sensing Mode (General)
  • Housing Material_
  • Feature: RS-232
  • Feature: RS-485
  • RS-422
  • Laser Classification
  • Feature: IO Link
  • Feature: Wireless
  • Feature: Quick Disconnect
  • Quick Disconnect Type
  • Max Op. Relative NC Humidity
  • Feature: Chemical Resistant
  • Storage Temp
  • Number of Pins
  • Adjustments
  • Feature: Timing (Hold/Delay)
  • Input/Output
  • Min Response Time
  • Vibration
  • Mechanical Shock
  • Output Saturation Voltage PNP Outputs
  • Analog Resolution/Discrete Repeatability
  • Max Discrete (Switched) Output (mA)
  • Min Sensing Distance
  • Min Window Size
  • Remote Teach and Laser Control Input Impedence
  • Discrete (Switched) Outputs
  • Max Measurement Range
  • Output Protection
  • Profibus
  • Feature: Remote Teach
  • Output Saturation Voltage NPN Outputs
  • Supply Protection Circuitry
  • Spot Size (@ Reference Distance)
  • Feature: Analog Output(s)
  • Connection Type
  • Country of Origin
  • NEMA / UL
  • Feature: Common Ethernet Protocol
  • Feature: Health/Marginal Signal Output
  • Feature: Laser Control
  • Feature: PC Configurable
  • Indicator Type
  • Max Ambient Light
  • Warm-Up Time
  • Discrete Output Hysteresis
  • Alarm Output (mA)
  • Analog Linearity

This combination does not exist.


Product Datasheets

Datasheet 1

Laser Displacement Sensor, LE550IQ-803009

  • Brand
  • Max Off-State Leakage Current (µA)
  • Analog Current Output Rating
  • Min Operating Temperature
  • Max Operating Temperature
  • Power/Current Consumption (exclusive of load)
  • Power Supply
  • Temperature Effect (mm/°C)
  • Delay at Power-Up
  • Ingress Protection
  • Sensing Beam
  • Sensing Beam Wavelength
  • Housing Style
  • Max Sensing Distance
  • Sensing Mode (Detailed)
  • Sensing Mode (General)
  • Housing Material_
  • Feature: RS-232
  • Feature: RS-485
  • RS-422
  • Laser Classification
  • Feature: IO Link
  • Feature: Wireless
  • Feature: Quick Disconnect
  • Quick Disconnect Type
  • Max Op. Relative NC Humidity
  • Feature: Chemical Resistant
  • Storage Temp
  • Number of Pins
  • Adjustments
  • Feature: Timing (Hold/Delay)
  • Input/Output
  • Min Response Time
  • Vibration
  • Mechanical Shock
  • Output Saturation Voltage PNP Outputs
  • Analog Resolution/Discrete Repeatability
  • Max Discrete (Switched) Output (mA)
  • Min Sensing Distance
  • Min Window Size
  • Remote Teach and Laser Control Input Impedence
  • Discrete (Switched) Outputs
  • Max Measurement Range
  • Output Protection
  • Profibus
  • Feature: Remote Teach
  • Output Saturation Voltage NPN Outputs
  • Supply Protection Circuitry
  • Spot Size (@ Reference Distance)
  • Feature: Analog Output(s)
  • Connection Type
  • Country of Origin
  • NEMA / UL
  • Feature: Common Ethernet Protocol
  • Feature: Health/Marginal Signal Output
  • Feature: Laser Control
  • Feature: PC Configurable
  • Indicator Type
  • Max Ambient Light
  • Warm-Up Time
  • Discrete Output Hysteresis
  • Alarm Output (mA)
  • Analog Linearity

1,138.00 1138.0 USD 1,138.00

1,138.00

Not Available For Sale

This combination does not exist.


Brand:Banner
Max Off-State Leakage Current (µA):<200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP)
Analog Current Output Rating:1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
Min Operating Temperature:-20 °C
Max Operating Temperature:55 °C
Power/Current Consumption (exclusive of load):70 mA @ 24 V dc
Power Supply:12-30 VDC
Temperature Effect (mm/°C):#ERROR
Delay at Power-Up:2000 ms
Ingress Protection:IP67
Sensing Beam:Visible Red Laser
Sensing Beam Wavelength:650
Housing Style:Rectangular
Max Sensing Distance:1000 mm
Sensing Mode (Detailed):Triangulation
Sensing Mode (General):Proximity
Housing Material_:Zinc Alloy Die-Cast
Feature: RS-232:No
Feature: RS-485:No
RS-422:No
Laser Classification:Class 2
Feature: IO Link:No
Feature: Wireless:No
Feature: Quick Disconnect:Yes
Quick Disconnect Type:M12
Max Op. Relative NC Humidity:90% @ 55 °C
Feature: Chemical Resistant:No
Storage Temp:-30 to 65 °C
Number of Pins:5
Adjustments:Push Button; Remote Teach
Feature: Timing (Hold/Delay):Yes
Input/Output:Analog & Discrete
Min Response Time:2 ms
Vibration:MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock:IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage PNP Outputs:< 3 V @ 100 mA
Analog Resolution/Discrete Repeatability:100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1
Max Discrete (Switched) Output (mA):100
Min Sensing Distance:100 mm
Min Window Size:10 mm
Remote Teach and Laser Control Input Impedence:18 kΩ min. (65 kΩ min at 5 V dc)
Discrete (Switched) Outputs:2 NPN/PNP Configurable
Max Measurement Range:500-1000 mm
Output Protection:Protected against continuous overload and short circuit
Profibus:No
Feature: Remote Teach:Yes
Output Saturation Voltage NPN Outputs:<1.6 V @ 100 mA
Supply Protection Circuitry:Protected against reverse polarity and transient overvoltages
Spot Size (@ Reference Distance):4.9 mm x 12.1 mm @ 1 m
Feature: Analog Output(s):4 to 20 mA
Connection Type:Integral QD
Country of Origin:US
NEMA / UL:NEMA 6
Feature: Common Ethernet Protocol:No
Feature: Health/Marginal Signal Output:Yes
Feature: Laser Control:Yes
Feature: PC Configurable:No
Indicator Type:LCD/LED
Max Ambient Light:10000 lux
Warm-Up Time:10 min
Discrete Output Hysteresis:Auto Adjust
Alarm Output (mA):100
Analog Linearity:Lesser of Accuracy or 0.5% FS (±4.5 mm)


Specifications

Brand Banner
Max Off-State Leakage Current (µA) <200 µA @ 30 VDC (NPN) / <10 µA @ 30 VDC (PNP)
Analog Current Output Rating 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
Min Operating Temperature -20 °C
Max Operating Temperature 55 °C
Power/Current Consumption (exclusive of load) 70 mA @ 24 V dc
Power Supply 12-30 VDC
Temperature Effect (mm/°C) #ERROR
Delay at Power-Up 2000 ms
Ingress Protection IP67
Sensing Beam Visible Red Laser
Sensing Beam Wavelength 650
Housing Style Rectangular
Max Sensing Distance 1000 mm
Sensing Mode (Detailed) Triangulation
Sensing Mode (General) Proximity
Housing Material_ Zinc Alloy Die-Cast
Feature: RS-232 No
Feature: RS-485 No
RS-422 No
Laser Classification Class 2
Feature: IO Link No
Feature: Wireless No
Feature: Quick Disconnect Yes
Quick Disconnect Type M12
Max Op. Relative NC Humidity 90% @ 55 °C
Feature: Chemical Resistant No
Storage Temp -30 to 65 °C
Number of Pins 5
Adjustments Push Button; Remote Teach
Feature: Timing (Hold/Delay) Yes
Input/Output Analog & Discrete
Min Response Time 2 ms
Vibration MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage PNP Outputs < 3 V @ 100 mA
Analog Resolution/Discrete Repeatability 100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1
Max Discrete (Switched) Output (mA) 100
Min Sensing Distance 100 mm
Min Window Size 10 mm
Remote Teach and Laser Control Input Impedence 18 kΩ min. (65 kΩ min at 5 V dc)
Discrete (Switched) Outputs 2 NPN/PNP Configurable
Max Measurement Range 500-1000 mm
Output Protection Protected against continuous overload and short circuit
Profibus No
Feature: Remote Teach Yes
Output Saturation Voltage NPN Outputs <1.6 V @ 100 mA
Supply Protection Circuitry Protected against reverse polarity and transient overvoltages
Spot Size (@ Reference Distance) 4.9 mm x 12.1 mm @ 1 m
Feature: Analog Output(s) 4 to 20 mA
Connection Type Integral QD
Country of Origin US
NEMA / UL NEMA 6
Feature: Common Ethernet Protocol No
Feature: Health/Marginal Signal Output Yes
Feature: Laser Control Yes
Feature: PC Configurable No
Indicator Type LCD/LED
Max Ambient Light 10000 lux
Warm-Up Time 10 min
Discrete Output Hysteresis Auto Adjust
Alarm Output (mA) 100
Analog Linearity Lesser of Accuracy or 0.5% FS (±4.5 mm)