Representative photo. Please check item description for details.

T18-2 Series: Fixed Field, T18-2VNFF200-2M

https://www.branom.com/web/image/product.template/45400/image_1920?unique=67ab7dc
(0 review)

Manufacturer: Banner Engineering Corp

Mfg Product Code: 802677

Weight: 0.2 lb(s)

On Hand: 0

T18-2 Series: Fixed Field

Features:

  • T18-2 Series: Fixed Field
  • Range: 200 mm
  • Input: 10-30 V dc
  • Outputs: complementary NPN
  • Connection: 4-conductor 2 m PVC Cable

126.00 126.0 USD 126.00

126.00

Not Available For Sale

  • Measurement Maximum
  • Min Operating Temperature
  • Max Operating Temperature
  • Lens Material
  • Power Supply
  • Delay at Power-Up
  • Measurement Minimum
  • Ingress Protection
  • Repeatability (µs)
  • Sensing Beam
  • Sensing Beam Wavelength
  • Housing Style
  • Max Sensing Distance
  • Sensing Mode (Detailed)
  • Sensing Mode (General)
  • Max Relative Humidity
  • Housing Material_
  • Feature: Washdown Rated
  • Feature: Hazardous Area
  • DeviceNet
  • Feature: IO Link
  • Feature: Quick Disconnect
  • Feature: Audible
  • Feature: Chemical Resistant
  • Feature: Chemical Resistant
  • Feature: Ecolab Certified
  • Feature: Water Detection
  • Number of Pins
  • Output Response Time
  • Operation
  • Adjustments
  • Feature: Timing (Hold/Delay)
  • Small Visible Spot
  • Feature: Encapsulated
  • Input/Output
  • Barrel Diameter
  • Feature: Remote Teach
  • Feature: Intrinsically Safe
  • Connection Type
  • Country of Origin
  • NEMA / UL
  • Cord/Cable Length
  • Indicator Type

This combination does not exist.

T18-2 Series: Fixed Field, T18-2VNFF200-2M

  • Measurement Maximum
  • Min Operating Temperature
  • Max Operating Temperature
  • Lens Material
  • Power Supply
  • Delay at Power-Up
  • Measurement Minimum
  • Ingress Protection
  • Repeatability (µs)
  • Sensing Beam
  • Sensing Beam Wavelength
  • Housing Style
  • Max Sensing Distance
  • Sensing Mode (Detailed)
  • Sensing Mode (General)
  • Max Relative Humidity
  • Housing Material_
  • Feature: Washdown Rated
  • Feature: Hazardous Area
  • DeviceNet
  • Feature: IO Link
  • Feature: Quick Disconnect
  • Feature: Audible
  • Feature: Chemical Resistant
  • Feature: Chemical Resistant
  • Feature: Ecolab Certified
  • Feature: Water Detection
  • Number of Pins
  • Output Response Time
  • Operation
  • Adjustments
  • Feature: Timing (Hold/Delay)
  • Small Visible Spot
  • Feature: Encapsulated
  • Input/Output
  • Barrel Diameter
  • Feature: Remote Teach
  • Feature: Intrinsically Safe
  • Connection Type
  • Country of Origin
  • NEMA / UL
  • Cord/Cable Length
  • Indicator Type

126.00 126.0 USD 126.00

126.00

Not Available For Sale

This combination does not exist.


T18-2 Series: Fixed Field


Measurement Maximum:0
Min Operating Temperature:-40 °C
Max Operating Temperature:70 °C
Lens Material:Acrylic
Power Supply:10-30 VDC
Delay at Power-Up:500 ms
Measurement Minimum:0
Ingress Protection:IP67/68/69
Repeatability (µs):100
Sensing Beam:Visible Red LED
Sensing Beam Wavelength:624
Housing Style:Barrel
Max Sensing Distance:200 mm
Sensing Mode (Detailed):Background Suppression (Fixed)
Sensing Mode (General):Proximity
Max Relative Humidity:95% @ 50 °C
Housing Material_:Thermoplastic
Feature: Washdown Rated:Yes
Feature: Hazardous Area:No
DeviceNet:No
Feature: IO Link:No
Feature: Quick Disconnect:No
Feature: Audible:No
Feature: Chemical Resistant:Yes, Yes
Feature: Ecolab Certified:Yes
Feature: Water Detection:No
Number of Pins:4
Output Response Time:1.5 ms
Operation:Light/Dark Operate
Adjustments:N/A
Feature: Timing (Hold/Delay):No
Small Visible Spot:LED
Feature: Encapsulated:Yes
Input/Output:Discrete
Barrel Diameter:18 mm
Feature: Remote Teach:No
Feature: Intrinsically Safe:No
Connection Type:Cable
Country of Origin:US
NEMA / UL:NEMA 6P
Cord/Cable Length:2 m
Indicator Type:Indicator LED


Specifications

Measurement Maximum 0
Min Operating Temperature -40 °C
Max Operating Temperature 70 °C
Lens Material Acrylic
Power Supply 10-30 VDC
Delay at Power-Up 500 ms
Measurement Minimum 0
Ingress Protection IP67/68/69
Repeatability (µs) 100
Sensing Beam Visible Red LED
Sensing Beam Wavelength 624
Housing Style Barrel
Max Sensing Distance 200 mm
Sensing Mode (Detailed) Background Suppression (Fixed)
Sensing Mode (General) Proximity
Max Relative Humidity 95% @ 50 °C
Housing Material_ Thermoplastic
Feature: Washdown Rated Yes
Feature: Hazardous Area No
DeviceNet No
Feature: IO Link No
Feature: Quick Disconnect No
Feature: Audible No
Feature: Chemical Resistant Yes, Yes
Feature: Ecolab Certified Yes
Feature: Water Detection No
Number of Pins 4
Output Response Time 1.5 ms
Operation Light/Dark Operate
Adjustments N/A
Feature: Timing (Hold/Delay) No
Small Visible Spot LED
Feature: Encapsulated Yes
Input/Output Discrete
Barrel Diameter 18 mm
Feature: Remote Teach No
Feature: Intrinsically Safe No
Connection Type Cable
Country of Origin US
NEMA / UL NEMA 6P
Cord/Cable Length 2 m
Indicator Type Indicator LED