Representative photo. Please check item description for details.

LH-10 with LevelGuard, 0-5psi, 40FT Cable

https://www.branom.com/web/image/product.template/483753/image_1920?unique=c569055
(0 review)

Manufacturer: Wika Instrument Lp

Mfg Product Code: 52756378

Weight: 10.0 lb(s)

On Hand: 0

Level Probe Model LH-10
High performance version
Specifications according to data sheet: PE 81.09
Accuracy: 0.25% of Span (with Pressure Ranges < 250 mbar: 0.5% of Span)
Permissible medium temperature: -10...+50°C (+14...+122°F) with Teflon cable -10...+85°C
(+14...+185°F)
Ingress Protection: IP 68
Special Protection: Longitudinal water resistance
Output signal: 4 ... 20 mA, 2-wire
Pressure Range: 0 ... 5 psi
Process Connection: G 1/2 B
Cable Length: 40 ft
Accessories process connection: Level Guard
Power supply: 10...30 V DC
pin assignment el. connection: UB=BN, 0V=GN

Features:

  • Level Probe Model LS-10
  • Specifications according to data sheet: PE 81.55
  • Accuracy: 0.5% of span
  • Power Supply: DC 10 ... 30 V
  • Output signal: 4 ... 20 mA, 2-wire
  • Permissible medium temperature: -10 ... +50 °C (+14 ... +122 °F)
  • Ingress Protection: IP 68
  • Material of Wetted Parts: 316 SS, Polyurethane, Polyamid
  • Pressure Range: 0 ... 5 psi
  • Process Connection: G 1/2 B
  • Cable Length: 15 m
  • Accessories process connection: Level Guard

1,667.08 1667.08 USD 1,667.08

1,667.08

Not Available For Sale

  • Measurement Maximum
  • Measurement Minimum
  • Output Communication Protocol
  • Input Voltage
  • Ingress Protection

This combination does not exist.

LH-10 with LevelGuard, 0-5psi, 40FT Cable

  • Measurement Maximum
  • Measurement Minimum
  • Output Communication Protocol
  • Input Voltage
  • Ingress Protection

1,667.08 1667.08 USD 1,667.08

1,667.08

Not Available For Sale

This combination does not exist.


Level Probe Model LH-10
High performance version
Specifications according to data sheet: PE 81.09
Accuracy: 0.25% of Span (with Pressure Ranges < 250 mbar: 0.5% of Span)
Permissible medium temperature: -10...+50°C (+14...+122°F) with Teflon cable -10...+85°C
(+14...+185°F)
Ingress Protection: IP 68
Special Protection: Longitudinal water resistance
Output signal: 4 ... 20 mA, 2-wire
Pressure Range: 0 ... 5 psi
Process Connection: G 1/2 B
Cable Length: 40 ft
Accessories process connection: Level Guard
Power supply: 10...30 V DC
pin assignment el. connection: UB=BN, 0V=GN


Measurement Maximum:5.0
Measurement Minimum:0
Output Communication Protocol:4-20 mA, 2-wire
Input Voltage:10-30 VDC
Ingress Protection:IP68


Specifications

Measurement Maximum 5.0
Measurement Minimum 0
Output Communication Protocol 4-20 mA, 2-wire
Input Voltage 10-30 VDC
Ingress Protection IP68